Sundyne LMV 341 OH6 Integrally Geared Pump

Safe, reliable and economical the Sundyne API 610, OH6, Integrally geared pump

Sundyne API 610, 11th Edition OH6 Integrally Gear Driven Pumps are engineered for critical high-head, low-flow, heavy-duty services required by process and rotating equipment engineers within the hydrocarbon, chemical, petrochemical, power generation, gas production, and specialty processing industries. Sundyne pumps are renowned for high suction pressure and a wide range of operating temperatures.

Unlike conventional multi-stage pumps, Sundyne computer tailored hydraulics place the B.E.P. (best efficiency point) at the rated point resulting in optimum efficiency.  An added benefit is reduced end-of-curve horsepower, allowing for smaller driver sizes resulting in energy savings.

  • Flows to 400 gpm (73 m³/hr)
  • Heads to 6,300 ft (1,348 m)
  • Suction Pressure 1,000 psi (71 kg/cm²)
  • Temperature Range -200 to 650°F (-130 to 340°C)

Multi-stage performance in a single stage pump

The vertical configuration of the integrally geared line of Sundyne pumps is specifically designed to save valuable space in refineries, NGL production, petrochemical and chemical plants.

APPLICATIONS

  • Feed pumps
  • Booster pumps
  • Bottoms pumps
  • Wash water pumps
  • Reflux pumps
  • Condensate pumps

Proven to be reliable, safe, compact and efficient, Sundyne LMV 311 OH6 integrally geared pumps provide a number of operational benefits:

  • Single stage, vertical in-line overhung pump according to ISO 13709/API 610 OH6 design recommendations for integrally geared pumps
  • Maximized up time
  • Saves space-25% the size of competing horizontal pumps
  • ATEX certified
  • Continuous operations for 5 years with no overhaul
  • Barske impeller low NPSH technology
  • Optimized pump engineering to meet the BEP – Best Efficiency Point to save energy through efficiency

US 60 Hz

  • Heads to                                                  6,300 ft
  • Flows to                                                   400 gpm
  • Standards                                               API 610 OH6
  • Maximum Motor Power                           400 HP
  • Temperature Range                                -200 to 650°F
  • Maximum Case Working Pressure          1,260 psi
  • Maximum Suction Pressure                     2,160 psi
  • Differential Head                                      6,300 ft
  • Maximum Viscosity                                  750 cp
  • Solids Range                                           0.015″, 400 microns
  • Mounting Configuration                           Vertical, Horizontal
  • Seal Configurations                                 Single, Double, Tandem
  • Available Inducer                                    Yes
  • Available Flanges       600# ANSI RF & RTJ, 900# RF & RTJ Optional
  • Suction and Discharge Size                3″ x 2″
  • API Plans     11, 12, 13, 21, 23, 31, 32, 41, 52, 53, 54, 61, 62, J

Metric 50 Hz

  • Heads to                                                  1,344 m
  • Flows to                                                   74 m3/hr
  • Standards                                                API 610
  • Maximum Motor Power                           315 kW
  • Temperature Range                                -130 to 340°C
  • Maximum Case Working Pressure         151.9 kg/cm2
  • Maximum Suction Pressure                     71 kg/cm²
  • Differential Head                                      1,344 m
  • Maximum Viscosity                                 750 cp
  • Solids Range                                           0.381mm, 400 microns
  • Mounting Configuration                           Vertical, Horizontal
  • Seal Configurations                                 Single, Double, Tandem
  • Available Inducer                                    Yes
  • Available Flanges     600# ANSI RF & RTJ, 900# RF & RTJ Optional
  • Suction and Discharge                           3″ x 2″
  • API Plans     11, 12, 13, 21, 23, 31, 32, 41, 52, 53, 54, 61, 62, J
  1. “O” build temperature range 0° to –240° F. Pressure capability is reduced due to strain hardened pump case studs. Contact Application Engineering.
  2. See Sundyne Corporation exceptions/clarifications to API 610, 11th edition for material requirements of pump parts.
  3. Impeller is upgraded to 316SS. A seal gland is not required because the seals mount in the seal housing. O-Rings are used instead of a case gasket.
  4. A seal gland is not required because the seals mount in the seal housing. The pump shaft is AISI 4140 because it is not exposed to the fluid. O-Rings are used instead of a case gasket.

Materials